Coal Dust Sampling Cassettes | Zefon International

Our coal dust cassettes use a sealed plastic capsule to create the outer shell of the device. The inner components use a 5-micron PVC filter for coal dust collection, and stainless steel supports the structure. Our products are preweighed to allow for precise air sampling for coal mines. We offer products for MSHA standards and nonregulated ...

Read More
KIT, PUMP MAINTENANCE PARTS | Zefon International

Coal Dust Sampling Cassettes, MSHA Mandated Sampling, 2 Pack. BATTERY, ESCORT PUMP, NiMH. Item No: 10087242. $306.00. Replacement battery pack for Zefon Escort, Escort ELF and Escort LC sampling pumps. NiMH, 4.8v, 2.8

Read More
Buy Coal Dust Collector/5 Micron PVC Filter | Zefon ...

Price:$55.00. Zefon’s Preweighed Coal Dust Sampling Cassettes consist of a sealed outer plastic capsule and an inner pre-weighed filter capsule. The inner capsule contains a 5 micron PVC filter, and stainless steel supports. Each filter cassette is supplied with a mine data card, which has the weight of the filter capsule recorded to the ...

Read More
4.8v Battery For Escort Elf Sampling Pump | Zefon ...

Coal Dust Sampling Cassettes, MSHA Mandated Sampling, 2 Pack. Related products. PUMP, ESCORT ELF WITH SAMPLING LINE. Item No: 805558. $981.00. Escort ELF personal sampling pump with sampling line. PUMP, ESCORT LC w/SAMPLING LINE. Item No: P1-ESLC-0

Read More
MSHA HANDBOOK SERIES

2021-4-15 · operator is conducting sampling upon arrival at the mine. Inspectors may sample other occupations and monitor the operator’s sampling if the operator cannot suspend sampling. Sample Duration . The sampling duration options are outlined below for the various types of sampling required. Respirable Dust, Total Dust, and Diesel Particulate Matter

Read More
Mine Safety and Health Administration(MSHA) - Status ...

2019-9-5 · Course materials, “Industrial Hygiene: Respirable Coal Dust and Silica Sampling” and “Control-Coal Refresher Training” are currently being developed to address all aspects of sampling, including penalties associated with tampering with samples and/or equipment. This material will be available for MSHA and industry training in March 1998. B

Read More
HRD-93-63 Mine Safety and Health: Tampering Scandal

2020-7-2 · now used in MSHA’ S respirable coal dust control program, that would provide superior coal dust sampling data. To answer these questions we reviewed pertinent legislation, regulations, and policies and obtained related documentation from MSHA, the

Read More
MSHA: INTRODUCTION TO OPERATOR AIR SAMPLING

2019-9-5 · INTRODUCTION TO OPERATOR AIR SAMPLING PROGRAMS. by Doris A. Cash. Health Division. Metal and Nonmetal Mine Safety and Health. 4015 Wilson Blvd. Arlington, VA 22203. BACKGROUND. Exposure to respirable

Read More
Sampling and analysis method for measuring airborne coal ...

Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively.

Read More
CDC - Mining - Coarse Coal Dust Sampling - NIOSH

Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high

Read More
Air Sampling Pumps | Envco

2022-1-15 · Cassette Sampling . 803462-2PK - Coal dust filter cassette: Preweighed filter cassestte with 5u pore size PVC filter and Mine Data Card - Coal Dust - MSHA mandated sampling. 711361 - Coal Dust and/ or Silica

Read More
Mine Owner and Foreman Sentenced To Prison For Dust ...

2020-8-12 · Upon further investigation, MSHA determined that Tucker and Ball had conducted an organized effort to avoid accurate dust sampling in an attempt to avoid MSHA health violations and avoid requirements to reduce the respirable coal dust levels. As part of MSHA’s mandatory respirable dust standards, mine operators are mandated to conduct dust ...

Read More
Deposition Uniformity of Coal Dust on Filters and Its ...

Three types of 37-mm plastic sample cassettes were chosen; 3-piece, 2-piece, and the approved (MSA/Zefon) tamper-proof cassettes used for respirable dust sampling in coal mines. Using standard convention, the flow rate for the 2- and 3-piece cassettes was 1.7 lpm, and for the MSA cassettes 2.0 lpm.

Read More
CDC - Mining - Sampling and Analysis Method -

Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To

Read More
CHAPTER 5 MINERAL DUSTS - GRAVIMETRIC METHOD

2021-10-19 · D. Total Dust Sampling Train Total dust sampling uses the same type of filter cassette required for respirable dust sampling. Assemble the apparatus with O-rings placed on the top and bottom of the cassette to seat the cassette snugly in the cassette holder (refer to Figure 5-4), or use the top of the metal cyclone holder seated into the cassette

Read More
MSHA: INTRODUCTION TO OPERATOR AIR

2019-9-5 · INTRODUCTION TO OPERATOR AIR SAMPLING PROGRAMS. by Doris A. Cash. Health Division. Metal and Nonmetal Mine Safety and Health. 4015 Wilson Blvd. Arlington, VA 22203. BACKGROUND. Exposure to

Read More
Evaluation of the SKC® DPM Cassette for Monitoring

2012-8-29 · while most coal dust particles have aerodynamic diameters greater than I !lm. Thus, a size-selective sampler can be used to separate most of the DPM from coal dust. Based on particle mass, the BOM sampler was 90% effective in the exclusion of coal dust, so about 10% of the dust was collected by the sample filter.

Read More
KEYSTONE COAL MINING V. SOL (MSHA) (94040857)

II. THE MINE-SPECIFIC TRIAL -- SAMPLING AND AWCs A. HANDLING OF DUST PUMPS AND CASSETTES AT URLING 1. THE ESD DUST LAB The respirable dust sampling program for Urling, as well as for all R & P mines, has been conducted by R & P's Environmental Safety Department (ESD) under the supervision of Donald Eget since 1970.

Read More
Quartz in Coal Dust Deposited on Internal Surface of ...

2022-1-23 · A chamber study evaluating wall loss mass between different types of respirable particle size-selective samplers when sampling for quartz laden coal dust was conducted by Charm, Kashon, & Harper ...

Read More
Industrial Hygiene Sampling Manual

2012-9-23 · MSHA would sample the entire 12-hour shift, then shift-weight the result to compare to ... Below are typical flow rates in liters per minute (lpm) for various contaminate sampling: • Respirable dust.....1.700 lpm • Lead.....1.700 lpm – 2.000 lpm ... used in order to accumulate more particulates on the sample cassettes. (If there is an

Read More
Sampling and analysis method for measuring airborne coal ...

Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively.

Read More
(PDF) Comparison of Coarse Coal Dust Sampling

Comparison of Coarse Coal Dust Sampling Techniques in a Laboratory-Simulated Longwall Section ... coarse dust assessments over “off-the-shelf” sampling cassettes. ... to the MSHA nuisance dust ...

Read More
Coal Mine Dust Sampling System - kenelec.au

2019-6-3 · when sampling for coal mine dust. The cylone is used to separate respirable dust particles from non-respirable particles and is specifi ed for use in coal mine dust sampling per 30 CFR, part 74. Coal Mine Dust Sampling System Escort® ELF Pump The Escort ELF pump is designed for use in coal mine dust sam-pling as specifi ed in 30 CFR Part 74.

Read More
Mine Safety and Health Administration (MSHA) - Federal ...

2014-7-18 · Coal mine operators are required to submit accurate dust samples on filter cassettes to MSHA for measurement ofthe quantity ofrespirable coal dust in the mine atmosphere. 15 FMSHRC at 1457; 30 C.F.R. §§ 70.201-220,71.201-220,and 90.201-220. These samples are taken in a sampling unit, consisting ofa pump, hose, cyclone assembly, and plastic ...

Read More
U.S. GAO - Mine Safety and Health: Tampering Scandal

1993-2-25 · Pursuant to a congressional request, GAO reviewed the Mine Safety and Health Administration's (MSHA) development and use of tamper-resistant devices, particularly cassettes and pumps, for collecting coal dust samples in its respirable coal dust program.GAO found that: (1) before the Secretary of Labor's 1991 announcement of massive tampering with coal dust

Read More
FEDERAL MINE SAFETY AND HEALTH REVIEW

Coal mine operators are required to submit accurate dust samples on filter cassettes to MSHA for measurement of the quantity of respirable coal dust in the mine atmosphere. 15 FMSHRC at 1457; 30 C.F.R. '' 70.201-220, 71.201-220, and 90.201-220. These samples are

Read More
SME Annual Conference & Expo - msha.gov

2019-8-20 · MSHA.GOV | @USDOL #MSHA Dust Sampling Trends • Increased sampling of key positions in coal mines was mandated by 2014 dust rule • What trends are we seeing? 8. MSHA.GOV | @USDOL #MSHA 90,803 93,911 80,627 73,313 81,548 82,293 76,812 76,974 88,556 76,304 75,262 79,174 74,289 66,534

Read More
Fact Sheet MSHA’s Final Rule to Lower Miners' Exposure

2014-7-31 · MSHA’s Final Rule to Lower Miners' Exposure to ... lung disease by issuing a final rule to reduce miners’ exposure to respirable coal dust. The new rule takes effect August 1, 2014 and accomplishes the following: ... Requires more frequent sampling of areas known to have high dust levels, such as those

Read More
CHAPTER 5 MINERAL DUSTS - GRAVIMETRIC METHOD

2021-10-19 · D. Total Dust Sampling Train Total dust sampling uses the same type of filter cassette required for respirable dust sampling. Assemble the apparatus with O-rings placed on the top and bottom of the cassette to seat the cassette snugly in the cassette holder (refer to Figure 5-4), or use the top of the metal cyclone holder seated into the cassette

Read More
Industrial Hygiene Sampling Manual

2012-9-23 · MSHA would sample the entire 12-hour shift, then shift-weight the result to compare to ... Below are typical flow rates in liters per minute (lpm) for various contaminate sampling: • Respirable dust.....1.700 lpm • Lead.....1.700 lpm – 2.000 lpm ... used in order to accumulate more particulates on the sample cassettes. (If there is an

Read More